My Cart

0 item(s)-$0.00
You have no items in your shopping cart.

0

More Views

Switching Mode Power Supply MSF150-48

Availability: Shipping directly from South Korea. Import duties are included

Estimated delivery : 14 Days

$160.00

Quick Overview

Product Features

• Part: Switching Mode Power Supply MSF150-48
• Manufacturer Part Number: 702MSF15048
• Manufacturer: Fine Suntronix. Orient electronics
OR

Details

Product Description

  • • Over current protection
  • • Over voltage protection
  • • Complies with FCC Part 15 and EN 5022
  • • Class A Limits
  • • Remote Sensing

Electrical Specifications
MODEL MSF200-24 MSF200-28 MSF200-36 MSF200-48
INPUT VOLTAGE, FREQUENCY AC100-120V / 200-240V (AC 90~ 132V / 180 ~ 264V or AC 225 ~ 370V), 50/60Hz (47 ~ 440Hz) User Selectable
CURRENT [A] 110V 4.1 ( I₀=100%)
220V 2.0 (I₀=100%)
EFFICIENCY [%] 110V 80 typ 80 typ 82 typ 82 typ
220V
INRUSH CURRENT 15A typ(ACIN 110V, I₀=100%), 30A typ(ACIN 220V, I₀=100%) at cold start.
OUTPUT VOLTAGE [V] 24 28 36 48
CURRENT [A] 8.3 7.1 5.5 4.1
REGULATION, LINE [mV] 120 Max 140 Max 180 Max 240 Max
REGULATION, LOAD [mV] 240 Max 280 Max 360 Max 480 Max
RIPPLE [mVp-p] 240 Max 280 Max 360 Max 480 Max
RIPPLE, NOISE [mVp-p] 290 Max 330 Max 410 Max 530 Max
TEMPERATURE DRIFT 0~+50℃ [mV] 360 Max 420 Max 540 Max 720 Max
RISE TIME [ms] 800 max (AC IN 110V, I₀=100%)
HOLDING TIME [ms] 15 typ (AC IN 110V, I₀=100%)
PROTECTION CIRCUIT OVER CURRENT PROTECTION Works at over 110% of rating and recovers automatically
OVER VOLTAGE PROTECTION Works at 115 ~ 140% of rating
ELECTRICALLY ISOLATED INPUT-OUTPUT AC 3,000V 1 minute current 20mA, DC 500V 100MΩ (At room temperature & humidity)
INPUT-CASE, FG AC 2,000V 1 minute current 20mA, DC 500V 100MΩ (At room temperature & humidity)
OUTPUT-CASE, FG AC 500V 1 minute current 100mA, DC 500V 100MΩ (At room temperature & humidity)
ENVIRONMENT OPERATING TEMP AND HUMID -10 ~ +50℃, 20 ~ 90% RH(Non condensing)
STORAGE TEMP AND HUMID -20 ~ +75℃, 20 ~ 90% RH(Non condensing)
VIBRATION 10 ~ 55Hz at 1G, 3 minutes period, 30 minutes along   X, Y and Z axis
IMPACT 10G for 20ms once on each X, Y and Z axis
SAFETY SAFETY REGULATION UL, C-UL, CE UL, C-UL, CE UL, C-UL, CE UL, C-UL, CE
LINE CONDUCTED RF VOLTAGE Complied with FCC Part15 and EN55022 Class A Limits